Oxygeneo Machine Safety Instructions and Contraindications
In Dubai’s highly regulated medical and aesthetic landscape, beauty and dermatology clinics must balance compliance with patient safety when integrating
More Posts

In Dubai’s highly regulated medical and aesthetic landscape, beauty and dermatology clinics must balance compliance with patient safety when integrating

Many skincare enthusiasts walk into their first OxyGeneo session expecting instant transformation, a glowing, lifted face in just one go.
Send Us A Message
In the fast-paced beauty and wellness scene of Dubai, even a brief downtime of the OxyGeneo machine during peak hours can disrupt appointments and negatively impact client satisfaction. Poor maintenance often leads to avoidable technical issues, cutting into valuable business hours. This is where proactive OxyGeneo machine maintenance becomes essential, not just for performance, but for reliability. This article serves as a complete guide for practitioners, outlining how to properly maintain, troubleshoot, and service their OxyGeneo device to ensure smooth operations, prevent costly interruptions, and keep every treatment session running at its professional best.
Get the OxyGeneo Facial Machine from Skyline Medical – the all-in-one solution for exfoliation, oxygenation, and deep nourishment.
Proper OxyGeneo maintenance begins with regular care and attention to key components such as handpieces, filters, and gel applicators. Maintaining a consistent schedule is crucial to ensure your OxyGeneo machine continues to operate safely and efficiently. To simplify the process, the recommended service routine is divided into two parts:
In the following sections, we’ll take a closer look at what each step involves to keep your device performing at its best.
To ensure consistent performance and extend the lifespan of your device, it’s essential to follow these OxyGeneo machine maintenance cleaning instructions as part of your daily routine. However, before starting any cleaning, always turn off the unit and unplug it from the power source to ensure complete safety.
To maintain optimal hygiene and functionality after each use, perform the following quick yet crucial cleaning steps:
Follow safety protocols: Never allow water or cleaning solutions to enter the system, and ensure all parts are completely dry before reconnecting power.
Beyond daily cleaning, maintaining your OxyGeneo facial machine requires a deeper inspection and care routine performed on a weekly and monthly basis. These steps ensure optimal device performance, minimize technical issues, and uphold safety standards in busy clinic environments.
To keep your system running smoothly, incorporate the following geneO+ maintenance practices into your schedule:
➕ Read more about What Is an Oxygeneo Machine?
If your OxyGeneo machine malfunctions, turn it off and unplug it immediately to prevent further damage or safety risks.
When operating in a fast-paced clinic, especially in a city like Dubai, even a short downtime can disrupt schedules and reduce client satisfaction. Therefore, recognizing early warning signs and taking swift action is essential before contacting a professional OxyGeneo machine maintenance service.
The following are common signs of defects and the appropriate safety actions to take for each:
Even with proper Geneo+ maintenance, occasional technical issues may arise that require careful identification before taking action. Knowing how to recognize early signs of common errors can save time and prevent further damage. While some minor issues can be managed on-site, others demand professional attention to ensure safe operation and maintain warranty coverage. Here’s a structured guide to OxyGeneo troubleshooting:
First, check that the green LED on the applicator changes from constant to blinking green. If it stays constant, disconnect the applicator and reconnect it to an alternative inlet. Persistent issues after this step indicate a need to consult an authorized technician.
Ensure the applicator is properly connected and the green LED is illuminated. If a communication error continues even after switching ports, this signals an internal connection issue that requires professional service.
Confirm that only a Pollogen Disk On Key (DOK) with a newer version is connected. If the system fails to update after retrying different USB ports, the device should be serviced by qualified personnel to avoid corrupting the software.
Verify that the applicator is properly connected. If the green LED still does not illuminate, do not attempt self-repair. Contact your local distributor or authorized service center immediately.
If the system cannot be switched off normally, unplug the device and arrange for professional inspection to avoid electrical hazards.
Maintaining your OxyGeneo device in optimal condition is crucial for delivering consistent, high-quality facial treatments. The GENEO+ Kit includes essential components such as the body unit, base unit, OxyGeneo applicator, power supply, massager head, and Capsugen. For routine upkeep, it's advisable to have a reach to spare parts for OxyGeneo readily available. In Dubai, several suppliers offer a range of consumables, including replacement applicators, power supplies, and massager heads, ensuring your device remains in peak working condition.
Regarding consumables like OxyPods, these are designed for single-use, with each box containing six pods, each paired with a primer gel and serum. These pods are integral to the treatment process, delivering active ingredients that rejuvenate the skin. It's essential to monitor the lifespan of these consumables to ensure optimal results. Typically, OxyPods have a shelf life of several months, but it's crucial to check the expiration dates and storage conditions to maintain their efficacy.
For those seeking professional support, OxyGeneo repair services in Dubai are available to address any technical issues or maintenance needs. Regular servicing can extend the lifespan of your device and ensure it continues to perform at its best.
Proper OxyGeneo machine maintenance is the cornerstone of a smoothly running clinic and consistent treatment results. By following daily, weekly, and monthly care routines, identifying errors early, and ensuring spare parts and consumables are accessible, clinics can significantly reduce downtime, enhance device performance, and extend the lifespan of their investment. Prioritize your device’s care and keep it performing at its best. Stay proactive, follow the guidelines, and schedule regular checks to ensure uninterrupted, high-quality OxyGeneo sessions.
The OxyGeneo protocol involves a three-step facial treatment: exfoliation, infusion, and oxygenation, designed to revitalize and nourish the skin. After each session, it is essential to follow the OxyGeneo cleaning protocol recommended by the manufacturer, which includes disinfecting the applicator and massager head, properly disposing of single-use Capsugen pods, and wiping down the device with a soft, damp cloth to ensure hygiene and maintain optimal performance.
OxyPods are designed for single-use only, with each kit containing six pods. For optimal results and hygiene, clinicians should replace the OxyPods after every treatment session. Regular replacement is a key part of OxyGeneo maintenance, ensuring consistent treatment performance, preventing cross-contamination, and prolonging the lifespan of the device.
No. Cleaning the device according to the recommended OxyGeneo machine maintenance practices will not void the warranty. However, clinicians must avoid attempting any repairs or tampering with the machine’s internal parts, as unauthorized modifications can affect warranty coverage and may pose safety risks.