Cynosure Elite

SKU: CY0001

Quality, affordability, and warranty: The perfect combination.

The elite laser hair removal machine Cynosure Elite by CYNOSURE is a refurbished dual-wavelength (755 nm Alexandrite and 1064 nm Nd: YAG) aesthetic system designed to deliver:

  1. Dual wavelength performance improves treatment flexibility and ensures reliable results for all skin tones with the Cynosure Elite laser machine.
  2. Trusted US-engineered quality backed by the global reputation of Cynosure Laser.
  3. Multi-application capability enhances clinic services with the Cynosure Elite machine.
  4. Precise follicle targeting ensures consistent outcomes using the Cynosure Elite laser machine.
  5. Refurbished system offers cost efficiency without compromising Cynosure laser performance.

Available through a trusted medical equipment trading company, Skyline supplies verified refurbished aesthetic systems to help clinics scale services with confidence and efficiency.

Download Catalogue

Delivery Option:

In-Stock Items within the UAE: Delivery will take 3-7 working days.
Out of Stock Items: Please contact us to inquire about the estimated delivery time.
International Delivery: For orders outside the UAE, please contact us for an estimated delivery timeline.

Delivery Option

Free Returns

0 People watching this product now!

Cynosure Elite:  Advanced Laser Hair Technology:

The Cynosure Elite Plus is a unique laser Hair Removal system for a variety of cosmetic and medical applications.
 
It specializes in hair removal, skin tightening, scar reduction, pigmentation correction, and vascular lesion treatments.
 
With dual wavelengths (755 nm Alexandrite and 1064 nm Nd:YAG), it effectively treats all skin types, providing outstanding and consistent results.
Comprehensive Laser Treatments

✅ Suitable for all skin types

✅ Long-lasting hair reduction

✅ Treats benign pigmented lesions

✅ Reduces facial and leg veins

✅ Minimizes redness and pigmentation

✅ Diminishes wrinkles

✅ Quicker procedures with deeper penetration

✅ Customized treatments for individual patient needs

Cynosure Elite Features

✔️ Classic 755nm Wavelength: Delivers power and speed options up to 20J/cm² at an 18mm spot size and 2 Hertz, ensuring high melanin absorption for reliable, consistent, and permanent hair reduction, as well as the treatment of benign pigmented lesions.

 

✔️ High-Powered 1064nm Wavelength: Perfect for hair removal on darker and tanned skin, and effective for treating facial and leg veins, reducing redness, pigmentation, and wrinkles.

 

✔️ High Fluence with Large Spot Sizes: Ensures deeper penetration, quicker procedures, and optimal results.

 

✔️ Adjustable Spot Sizes and Pulse Widths: Offers up to 7 different spot sizes with adjustable pulse widths to customize treatments for specific patient needs.

 

✔️ Ergonomic Handpieces: Features a lightweight design with an optional air cooling system adaptor to enhance patient comfort

Cynosure Elite Benefits

👉 Versatility: The dual wavelengths (Alexandrite 755nm and Nd:YAG 1064nm) enable a broad range of treatments for all skin types.

👉 Effective Hair Removal: Achieves permanent hair reduction with high melanin absorption.

👉 Skin Rejuvenation: Promotes collagen production for skin tightening and wrinkle reduction.

👉 Pigmentation and Vascular Treatments: Successfully treats benign pigmented lesions, facial and leg veins, and reduces redness and pigmentation.

👉 Customizable Treatments: Adjustable spot sizes and pulse widths allow for personalized treatments tailored to individual patient needs.

👉 Patient Comfort: Ergonomic handpieces and an optional air cooling system enhance comfort during procedures.

👉 Fast and Efficient: High fluence with large spot sizes ensures deeper penetration and quicker procedures.

Cynosure laser machine UAE

How To Use The Cynosure Elite Laser?

⚙️ Consultation: Conduct a thorough consultation with the patient to understand their needs and medical history.

 

⚙️ Skin Assessment: Assess the patient’s skin type and condition to determine the appropriate settings.

 

⚙️ Power On: Turn on the Cynosure Elite Plus and allow it to initialize.

 

⚙️ Select Wavelength: Choose the appropriate wavelength (Alexandrite 755nm or Nd:YAG 1064nm) based on the treatment and skin type.

 

⚙️ Adjust Settings: Set the fluence, pulse duration, and spot size according to the treatment protocol and patient’s skin type.

⚙️ Clean the Treatment Area: Ensure the area to be treated is clean and free of any lotions or makeup.

 

⚙️ Protective Gear: Both the patient and the operator should wear protective eyewear.

 

⚙️ Test Spot: Perform a test spot to check for any adverse reactions.

 

⚙️ Treatment: Move the handpiece over the treatment area, ensuring consistent coverage. Use the appropriate technique for the specific treatment (e.g., hair removal, skin tightening).

 

⚙️ Cooling: Utilize the optional air cooling system to enhance patient comfort during the procedure.

⚙️ Aftercare Instructions: Provide the patient with post-treatment care instructions, such as avoiding sun exposure and using soothing creams.

 

⚙️  Follow-Up: Schedule follow-up appointments to monitor progress and perform additional treatments if necessary. 

 

⚙️ Regular Maintenance: Perform regular maintenance on the device as recommended by the manufacturer to ensure optimal performance.

Cynosure Elite Technical Specifications: What Sets This Cynosure Laser Apart?

The Cynosure Elite system technical specifications highlight the core performance parameters of the Cynosure laser to help clinics and medical professionals evaluate power output, treatment flexibility, and system requirements before purchase:

Specification Alexandrite (755 nm) Nd: YAG (1064 nm)
Pulse Width
Adjustable 0.5–300 msec
Adjustable 0.4–300 msec
Maximum Fluence at 15 mm
30 J/cm²
35 J/cm²
Maximum Fluence at 12 mm
45 J/cm²
50 J/cm²
Maximum Fluence at 10 mm
50 J/cm²
80 J/cm²
Maximum Fluence at 7 mm
60 J/cm²
160 J/cm²
Maximum Fluence at 5 mm
50 J/cm²
240 J/cm²
Maximum Repetition Rate
3 Hz
5 Hz
Aiming Beam
Red
Red
Skin Cooling System
Cold air available separately
Cold air available separately
Electrical Requirements
200 220 VAC 30A
200 220 VAC 30A
System Dimensions
41 x 15 x 25 inches
41 x 15 x 25 inches
Weight
180 lbs 82 kg
180 lbs 82 kg
Brand

CYNOSURE