Medical Autoclave 12L Class B model: Foster

SKU: FO0200-1

Reliable, Smart, and Efficient Sterilization

A high-performance 22L Class B autoclave designed for dental and medical clinics. Combining advanced technology with user-friendly operation, it ensures thorough sterilization with enhanced safety and convenience.

Key Features:

  • Smart touch keys & LED display panel

  • Double door locking-system for maximum safety

  • Water quality sensor for extended equipment life

  • Built-in USB for data logging and traceability

  • 99% saturated steam for complete sterilization

  • Italian pump & solenoid valve for reliability

  • Real-time sterilization tracking with program curve display

  • One-click program upgrade and fault self-test

  • Efficient drying with all-inclusive heating loop

  • Appointment function for scheduled operation

Capacity: 12 Liters
Ideal for: Dental clinics, medical centers, and surgical instrument sterilization.

Download CatalogsĀ 

Delivery Option:

In-Stock Items within the UAE: Delivery will take 3-7 working days.
Out of Stock Items: Please contact us to inquire about the estimated delivery time.
International Delivery: For orders outside the UAE, please contact us for an estimated delivery timeline.

0 People watching this product now!
Foster 12L Class B Autoclave – Full Specifications | Skyline Med
Why This Machine

Why a Class B Autoclave Matters in Your Clinic

European Class B sterilization is the highest reliability standard worldwide — the only class capable of fully sterilizing hollow instruments (like needles and fine tips) and pre-wrapped items with the same efficiency as solid instruments, thanks to repeated fractionated vacuum pulses before sterilization begins. The 12L Foster brings this same reliability to a compact footprint, ideal for smaller treatment rooms and single-chair clinics.

Foster 12L Class B autoclave with touch panel display
šŸŒ”ļø
134°C in 23 min Universal Class B cycle
12LCompact chamber capacity
99%Saturated steam
23 minUniversal cycle time
<0.2%Residual humidity
šŸ›”ļø

Double Protection for Staff & Patients

A double door locking-system (mechanical + electrical) that only releases once internal pressure has reached zero, for maximum safety at every stage.

šŸ“Š

Full Cycle Traceability

Built-in USB function for complete data logging and traceability of every sterilization cycle — records ready for audit and health authority compliance.

⚔

Real Operational Speed

Real-time sterilization tracking with a live program curve display, so you always know exactly where each cycle stands.

šŸ’§

Truly Dry Instruments

An all-inclusive heating loop delivers efficient drying, keeping residual humidity below 0.2% — instruments come out completely dry and ready for sterile storage.

šŸ”§

Longer Equipment Life

A water quality sensor extends equipment life by protecting internal components, while the Italian pump & solenoid valve add long-term reliability.

šŸ–„ļø

Effortless, Intuitive Control

Smart touch keys and a clear LED display panel, plus one-click program upgrade and fault self-test, and an appointment function for scheduled operation.

How a Sterilization Cycle Runs

Four monitored phases, displayed live on the control panel via the real-time program curve
1
Air RemovalRepeated vacuum pulses clear air from hollow instruments
2
Heating & Pressure99% saturated steam is generated and pressure is set automatically
3
SterilizationPrecise temperature holding throughout the cycle
4
DryingAll-inclusive heating loop for residual humidity below 0.2%
Manufacturer Data

Full Technical Specifications

12L European Class B model, built for dental clinics, medical centers, and surgical instrument sterilization.

Key Features

Class12L European Class B
Control panelSmart touch keys & LED display panel
Door safetyDouble door locking-system for maximum safety
Water quality sensorFor extended equipment life
Data loggingBuilt-in USB for data logging and traceability
Steam quality99% saturated steam for complete sterilization

Performance & Reliability

Pump & valveItalian pump & solenoid valve for reliability
Cycle monitoringReal-time sterilization tracking with program curve display
Maintenance toolsOne-click program upgrade and fault self-test
Drying systemEfficient drying with all-inclusive heating loop
SchedulingAppointment function for scheduled operation
Residual humidityLess than 0.2%

Capacity & Accessories

Capacity12 Liters
Instrument containers5 layers with 3 trays
Fresh water reservoir3.5 Liters
Waste water reservoir5 Liters
Dry procedureResidual humidity below 0.2%

Physical & Electrical

Chamber dimensionsƘ200 mm Ɨ 368 mm
External dimensions566 Ɨ 408 Ɨ 425 mm (WƗHƗD)
Net weight42 kg
VoltageAC 110V / 220V
Power1800 W
Current10 A

Ideal For

Dental clinicsRoutine instrument sterilization
Medical centersGeneral clinical sterilization needs
Surgical instrumentsSolid, hollow, and wrapped items
Inside the Machine

Build Quality & Core Components

Carefully selected components chosen for consistent performance and a long operating life under daily clinical use.

āš™ļø

Italian Pump & Solenoid Valve

Delivers stable water pressure and long-term reliability compared to standard alternatives.

šŸ”’

Double Door Locking-System

Mechanical and electrical locking that only releases once internal pressure reaches zero, for maximum safety.

šŸ’§

Water Quality Sensor

Monitors water quality continuously to reduce failure rates and extend equipment life.

šŸ–„ļø

Smart Touch Keys & LED Panel

Clear, responsive controls with a live LED display for straightforward daily operation.

šŸ“ˆ

Program Curve Display

Real-time sterilization tracking shows the live cycle curve for full visibility at every stage.

šŸ”Œ

Built-in USB Function

Logs and stores sterilization data automatically for traceability and compliance records.

Before First Use

Installation & Setup Requirements

Key steps to prepare your sterilization room before the unit is delivered and switched on for the first time.

1

Prepare a Stable Work Surface

Place the unit on a flat, stable surface, leaving clear ventilation space behind and beside it so heat can dissipate properly during operation.

2

Dedicated Power Supply

Use a grounded, dedicated power outlet matching the unit's electrical requirements to avoid fluctuations that could affect cycle accuracy.

3

Fill the Fresh Water Reservoir

Use distilled or demineralized water only in the 3.5L fresh water reservoir — the water quality sensor will alert you automatically if water quality is not suitable.

4

Level the Unit

Adjust the feet so the unit sits perfectly level, which is essential for correct door sealing and drainage.

5

Run the Initial Self-Test

Use the built-in fault self-test function on first power-up to confirm all components are working correctly before running your first real sterilization cycle.

6

Set Date, Time & Preferences

From the touch panel, set the date and time to ensure accurate traceability records logged through the built-in USB function.

Daily Operation

Running a Standard Sterilization Cycle

A simple, repeatable sequence for daily use in the clinic or medical center.

1

Load & Arrange Instruments

Distribute instruments across the 3 trays within the 5-layer containers, avoiding overcrowding so steam reaches every surface and cavity.

2

Select the Right Program

Choose the appropriate program from the smart touch panel based on the instrument type being sterilized.

3

Close the Door & Start the Cycle

Close the door until the double locking-system engages, then press start. The program curve display shows the live cycle in real time.

4

Monitor & Log

Once complete, the unit signals cycle end. Use the built-in USB function to export the cycle log for traceability and compliance.

5

Unload Dry Instruments

The door only unlocks once internal pressure reaches zero. Instruments come out with residual humidity below 0.2%, ready for sterile storage immediately.

6

Use the Appointment Function

Schedule a cycle in advance using the appointment function so the unit is ready before your clinic day begins.

Extending Equipment Life

Routine Maintenance & Troubleshooting

A simple maintenance routine keeps performance consistent and reduces faults, plus quick guidance for common alerts.

Daily Maintenance

  • Empty the waste water reservoir and refill the fresh water reservoir with distilled water.
  • Wipe the door gasket clean of any residue to ensure a tight seal.
  • Check trays and containers for buildup or discoloration.

Weekly / Monthly Maintenance

  • Clean the water filter and internal chamber screen to prevent line blockages.
  • Run the fault self-test to confirm all components are functioning correctly.
  • Visually inspect the power cable and grounding connection.

Periodic Advanced Maintenance (Every 6–12 Months)

  • Have temperature and pressure sensors calibrated by an authorized technician.
  • Inspect and replace the door gasket if needed.
  • Document sterilization effectiveness for regulatory records.

⚠ When the Water Quality Alert Appears

  • Stop using regular tap water immediately and switch to distilled or demineralized water.
  • Clean the fresh water reservoir of any mineral buildup.
  • If the alert continues after cleaning, contact technical support.

Ready to Equip Your Clinic with a Reliable Class B Solution?

Skyline provides delivery, installation, and after-sales technical support across the UAE, Oman, and Saudi Arabia.

Ā© 2026 Skyline for Medical Requisites — All rights reserved.
BrandFOMOS

Can’t Find the Product You’re Looking For?

Our sourcing team can help you find specific dental, derma, and medical equipment based on your clinic needs.