Medical Autoclave 12L Class B model: Foster
1,313 £ Original price was: 1,313 £.1,111 £Current price is: 1,111 £.
Reliable, Smart, and Efficient Sterilization
A high-performance 22L Class B autoclave designed for dental and medical clinics. Combining advanced technology with user-friendly operation, it ensures thorough sterilization with enhanced safety and convenience.
Key Features:
-
Smart touch keys & LED display panel
-
Double door locking-system for maximum safety
-
Water quality sensor for extended equipment life
-
Built-in USB for data logging and traceability
-
99% saturated steam for complete sterilization
-
Italian pump & solenoid valve for reliability
-
Real-time sterilization tracking with program curve display
-
One-click program upgrade and fault self-test
-
Efficient drying with all-inclusive heating loop
-
Appointment function for scheduled operation
Capacity: 12 Liters
Ideal for: Dental clinics, medical centers, and surgical instrument sterilization.
Delivery Option:
In-Stock Items within the UAE: Delivery will take 3-7 working days.
Out of Stock Items: Please contact us to inquire about the estimated delivery time.
International Delivery: For orders outside the UAE, please contact us for an estimated delivery timeline.
Why a Class B Autoclave Matters in Your Clinic
European Class B sterilization is the highest reliability standard worldwide — the only class capable of fully sterilizing hollow instruments (like needles and fine tips) and pre-wrapped items with the same efficiency as solid instruments, thanks to repeated fractionated vacuum pulses before sterilization begins. The 12L Foster brings this same reliability to a compact footprint, ideal for smaller treatment rooms and single-chair clinics.
Double Protection for Staff & Patients
A double door locking-system (mechanical + electrical) that only releases once internal pressure has reached zero, for maximum safety at every stage.
Full Cycle Traceability
Built-in USB function for complete data logging and traceability of every sterilization cycle — records ready for audit and health authority compliance.
Real Operational Speed
Real-time sterilization tracking with a live program curve display, so you always know exactly where each cycle stands.
Truly Dry Instruments
An all-inclusive heating loop delivers efficient drying, keeping residual humidity below 0.2% — instruments come out completely dry and ready for sterile storage.
Longer Equipment Life
A water quality sensor extends equipment life by protecting internal components, while the Italian pump & solenoid valve add long-term reliability.
Effortless, Intuitive Control
Smart touch keys and a clear LED display panel, plus one-click program upgrade and fault self-test, and an appointment function for scheduled operation.
How a Sterilization Cycle Runs
Full Technical Specifications
12L European Class B model, built for dental clinics, medical centers, and surgical instrument sterilization.
Key Features
| Class | 12L European Class B |
| Control panel | Smart touch keys & LED display panel |
| Door safety | Double door locking-system for maximum safety |
| Water quality sensor | For extended equipment life |
| Data logging | Built-in USB for data logging and traceability |
| Steam quality | 99% saturated steam for complete sterilization |
Performance & Reliability
| Pump & valve | Italian pump & solenoid valve for reliability |
| Cycle monitoring | Real-time sterilization tracking with program curve display |
| Maintenance tools | One-click program upgrade and fault self-test |
| Drying system | Efficient drying with all-inclusive heating loop |
| Scheduling | Appointment function for scheduled operation |
| Residual humidity | Less than 0.2% |
Capacity & Accessories
| Capacity | 12 Liters |
| Instrument containers | 5 layers with 3 trays |
| Fresh water reservoir | 3.5 Liters |
| Waste water reservoir | 5 Liters |
| Dry procedure | Residual humidity below 0.2% |
Physical & Electrical
| Chamber dimensions | Ø200 mm × 368 mm |
| External dimensions | 566 × 408 × 425 mm (W×H×D) |
| Net weight | 42 kg |
| Voltage | AC 110V / 220V |
| Power | 1800 W |
| Current | 10 A |
Ideal For
| Dental clinics | Routine instrument sterilization |
| Medical centers | General clinical sterilization needs |
| Surgical instruments | Solid, hollow, and wrapped items |
Build Quality & Core Components
Carefully selected components chosen for consistent performance and a long operating life under daily clinical use.
Italian Pump & Solenoid Valve
Delivers stable water pressure and long-term reliability compared to standard alternatives.
Double Door Locking-System
Mechanical and electrical locking that only releases once internal pressure reaches zero, for maximum safety.
Water Quality Sensor
Monitors water quality continuously to reduce failure rates and extend equipment life.
Smart Touch Keys & LED Panel
Clear, responsive controls with a live LED display for straightforward daily operation.
Program Curve Display
Real-time sterilization tracking shows the live cycle curve for full visibility at every stage.
Built-in USB Function
Logs and stores sterilization data automatically for traceability and compliance records.
Installation & Setup Requirements
Key steps to prepare your sterilization room before the unit is delivered and switched on for the first time.
Prepare a Stable Work Surface
Place the unit on a flat, stable surface, leaving clear ventilation space behind and beside it so heat can dissipate properly during operation.
Dedicated Power Supply
Use a grounded, dedicated power outlet matching the unit's electrical requirements to avoid fluctuations that could affect cycle accuracy.
Fill the Fresh Water Reservoir
Use distilled or demineralized water only in the 3.5L fresh water reservoir — the water quality sensor will alert you automatically if water quality is not suitable.
Level the Unit
Adjust the feet so the unit sits perfectly level, which is essential for correct door sealing and drainage.
Run the Initial Self-Test
Use the built-in fault self-test function on first power-up to confirm all components are working correctly before running your first real sterilization cycle.
Set Date, Time & Preferences
From the touch panel, set the date and time to ensure accurate traceability records logged through the built-in USB function.
Running a Standard Sterilization Cycle
A simple, repeatable sequence for daily use in the clinic or medical center.
Load & Arrange Instruments
Distribute instruments across the 3 trays within the 5-layer containers, avoiding overcrowding so steam reaches every surface and cavity.
Select the Right Program
Choose the appropriate program from the smart touch panel based on the instrument type being sterilized.
Close the Door & Start the Cycle
Close the door until the double locking-system engages, then press start. The program curve display shows the live cycle in real time.
Monitor & Log
Once complete, the unit signals cycle end. Use the built-in USB function to export the cycle log for traceability and compliance.
Unload Dry Instruments
The door only unlocks once internal pressure reaches zero. Instruments come out with residual humidity below 0.2%, ready for sterile storage immediately.
Use the Appointment Function
Schedule a cycle in advance using the appointment function so the unit is ready before your clinic day begins.
Routine Maintenance & Troubleshooting
A simple maintenance routine keeps performance consistent and reduces faults, plus quick guidance for common alerts.
Daily Maintenance
- Empty the waste water reservoir and refill the fresh water reservoir with distilled water.
- Wipe the door gasket clean of any residue to ensure a tight seal.
- Check trays and containers for buildup or discoloration.
Weekly / Monthly Maintenance
- Clean the water filter and internal chamber screen to prevent line blockages.
- Run the fault self-test to confirm all components are functioning correctly.
- Visually inspect the power cable and grounding connection.
Periodic Advanced Maintenance (Every 6–12 Months)
- Have temperature and pressure sensors calibrated by an authorized technician.
- Inspect and replace the door gasket if needed.
- Document sterilization effectiveness for regulatory records.
⚠ When the Water Quality Alert Appears
- Stop using regular tap water immediately and switch to distilled or demineralized water.
- Clean the fresh water reservoir of any mineral buildup.
- If the alert continues after cleaning, contact technical support.
Ready to Equip Your Clinic with a Reliable Class B Solution?
Skyline provides delivery, installation, and after-sales technical support across the UAE, Oman, and Saudi Arabia.
| Brand | FOMOS |
|---|
