Medical Autoclave 12L Class B model: Foster

SKU: FO0200-1

Original price was: 1,313 £.Current price is: 1,111 £.

Reliable, Smart, and Efficient Sterilization

A high-performance 22L Class B autoclave designed for dental and medical clinics. Combining advanced technology with user-friendly operation, it ensures thorough sterilization with enhanced safety and convenience.

Key Features:

  • Smart touch keys & LED display panel

  • Double door locking-system for maximum safety

  • Water quality sensor for extended equipment life

  • Built-in USB for data logging and traceability

  • 99% saturated steam for complete sterilization

  • Italian pump & solenoid valve for reliability

  • Real-time sterilization tracking with program curve display

  • One-click program upgrade and fault self-test

  • Efficient drying with all-inclusive heating loop

  • Appointment function for scheduled operation

Capacity: 12 Liters
Ideal for: Dental clinics, medical centers, and surgical instrument sterilization.

Delivery Option:

In-Stock Items within the UAE: Delivery will take 3-7 working days.
Out of Stock Items: Please contact us to inquire about the estimated delivery time.
International Delivery: For orders outside the UAE, please contact us for an estimated delivery timeline.

1 People watching this product now!
Foster 12L Class B Autoclave – Full Specifications | Skyline Med
Why This Machine

Why a Class B Autoclave Matters in Your Clinic

European Class B sterilization is the highest reliability standard worldwide — the only class capable of fully sterilizing hollow instruments (like needles and fine tips) and pre-wrapped items with the same efficiency as solid instruments, thanks to repeated fractionated vacuum pulses before sterilization begins. The 12L Foster brings this same reliability to a compact footprint, ideal for smaller treatment rooms and single-chair clinics.

Foster 12L Class B autoclave with touch panel display
🌡️
134°C in 23 min Universal Class B cycle
12LCompact chamber capacity
99%Saturated steam
23 minUniversal cycle time
<0.2%Residual humidity
🛡️

Double Protection for Staff & Patients

A double door locking-system (mechanical + electrical) that only releases once internal pressure has reached zero, for maximum safety at every stage.

📊

Full Cycle Traceability

Built-in USB function for complete data logging and traceability of every sterilization cycle — records ready for audit and health authority compliance.

Real Operational Speed

Real-time sterilization tracking with a live program curve display, so you always know exactly where each cycle stands.

💧

Truly Dry Instruments

An all-inclusive heating loop delivers efficient drying, keeping residual humidity below 0.2% — instruments come out completely dry and ready for sterile storage.

🔧

Longer Equipment Life

A water quality sensor extends equipment life by protecting internal components, while the Italian pump & solenoid valve add long-term reliability.

🖥️

Effortless, Intuitive Control

Smart touch keys and a clear LED display panel, plus one-click program upgrade and fault self-test, and an appointment function for scheduled operation.

How a Sterilization Cycle Runs

Four monitored phases, displayed live on the control panel via the real-time program curve
1
Air RemovalRepeated vacuum pulses clear air from hollow instruments
2
Heating & Pressure99% saturated steam is generated and pressure is set automatically
3
SterilizationPrecise temperature holding throughout the cycle
4
DryingAll-inclusive heating loop for residual humidity below 0.2%
Manufacturer Data

Full Technical Specifications

12L European Class B model, built for dental clinics, medical centers, and surgical instrument sterilization.

Key Features

Class12L European Class B
Control panelSmart touch keys & LED display panel
Door safetyDouble door locking-system for maximum safety
Water quality sensorFor extended equipment life
Data loggingBuilt-in USB for data logging and traceability
Steam quality99% saturated steam for complete sterilization

Performance & Reliability

Pump & valveItalian pump & solenoid valve for reliability
Cycle monitoringReal-time sterilization tracking with program curve display
Maintenance toolsOne-click program upgrade and fault self-test
Drying systemEfficient drying with all-inclusive heating loop
SchedulingAppointment function for scheduled operation
Residual humidityLess than 0.2%

Capacity & Accessories

Capacity12 Liters
Instrument containers5 layers with 3 trays
Fresh water reservoir3.5 Liters
Waste water reservoir5 Liters
Dry procedureResidual humidity below 0.2%

Physical & Electrical

Chamber dimensionsØ200 mm × 368 mm
External dimensions566 × 408 × 425 mm (W×H×D)
Net weight42 kg
VoltageAC 110V / 220V
Power1800 W
Current10 A

Ideal For

Dental clinicsRoutine instrument sterilization
Medical centersGeneral clinical sterilization needs
Surgical instrumentsSolid, hollow, and wrapped items
Inside the Machine

Build Quality & Core Components

Carefully selected components chosen for consistent performance and a long operating life under daily clinical use.

⚙️

Italian Pump & Solenoid Valve

Delivers stable water pressure and long-term reliability compared to standard alternatives.

🔒

Double Door Locking-System

Mechanical and electrical locking that only releases once internal pressure reaches zero, for maximum safety.

💧

Water Quality Sensor

Monitors water quality continuously to reduce failure rates and extend equipment life.

🖥️

Smart Touch Keys & LED Panel

Clear, responsive controls with a live LED display for straightforward daily operation.

📈

Program Curve Display

Real-time sterilization tracking shows the live cycle curve for full visibility at every stage.

🔌

Built-in USB Function

Logs and stores sterilization data automatically for traceability and compliance records.

Before First Use

Installation & Setup Requirements

Key steps to prepare your sterilization room before the unit is delivered and switched on for the first time.

1

Prepare a Stable Work Surface

Place the unit on a flat, stable surface, leaving clear ventilation space behind and beside it so heat can dissipate properly during operation.

2

Dedicated Power Supply

Use a grounded, dedicated power outlet matching the unit's electrical requirements to avoid fluctuations that could affect cycle accuracy.

3

Fill the Fresh Water Reservoir

Use distilled or demineralized water only in the 3.5L fresh water reservoir — the water quality sensor will alert you automatically if water quality is not suitable.

4

Level the Unit

Adjust the feet so the unit sits perfectly level, which is essential for correct door sealing and drainage.

5

Run the Initial Self-Test

Use the built-in fault self-test function on first power-up to confirm all components are working correctly before running your first real sterilization cycle.

6

Set Date, Time & Preferences

From the touch panel, set the date and time to ensure accurate traceability records logged through the built-in USB function.

Daily Operation

Running a Standard Sterilization Cycle

A simple, repeatable sequence for daily use in the clinic or medical center.

1

Load & Arrange Instruments

Distribute instruments across the 3 trays within the 5-layer containers, avoiding overcrowding so steam reaches every surface and cavity.

2

Select the Right Program

Choose the appropriate program from the smart touch panel based on the instrument type being sterilized.

3

Close the Door & Start the Cycle

Close the door until the double locking-system engages, then press start. The program curve display shows the live cycle in real time.

4

Monitor & Log

Once complete, the unit signals cycle end. Use the built-in USB function to export the cycle log for traceability and compliance.

5

Unload Dry Instruments

The door only unlocks once internal pressure reaches zero. Instruments come out with residual humidity below 0.2%, ready for sterile storage immediately.

6

Use the Appointment Function

Schedule a cycle in advance using the appointment function so the unit is ready before your clinic day begins.

Extending Equipment Life

Routine Maintenance & Troubleshooting

A simple maintenance routine keeps performance consistent and reduces faults, plus quick guidance for common alerts.

Daily Maintenance

  • Empty the waste water reservoir and refill the fresh water reservoir with distilled water.
  • Wipe the door gasket clean of any residue to ensure a tight seal.
  • Check trays and containers for buildup or discoloration.

Weekly / Monthly Maintenance

  • Clean the water filter and internal chamber screen to prevent line blockages.
  • Run the fault self-test to confirm all components are functioning correctly.
  • Visually inspect the power cable and grounding connection.

Periodic Advanced Maintenance (Every 6–12 Months)

  • Have temperature and pressure sensors calibrated by an authorized technician.
  • Inspect and replace the door gasket if needed.
  • Document sterilization effectiveness for regulatory records.

⚠ When the Water Quality Alert Appears

  • Stop using regular tap water immediately and switch to distilled or demineralized water.
  • Clean the fresh water reservoir of any mineral buildup.
  • If the alert continues after cleaning, contact technical support.

Ready to Equip Your Clinic with a Reliable Class B Solution?

Skyline provides delivery, installation, and after-sales technical support across the UAE, Oman, and Saudi Arabia.

© 2026 Skyline for Medical Requisites — All rights reserved.
BrandFOMOS

Can’t Find the Product You’re Looking For?

Our sourcing team can help you find specific dental, derma, and medical equipment based on your clinic needs.